Menu
1. First check whether the socket is powered normally and whether the power plug is loose;
2. If the socket is powered normally and the power switch indicator light is not on, then the power switch or fuse holder is faulty; open the device and check whether the power switch and fuse holder are melted.
3. If the power switch indicator light is on and powered normally, then the motor is faulty;
You need to open the device and check whether the heating plate connection terminal is blown. If it is not blown, the heating plate is faulty
1. If the socket is powered normally and the power switch indicator light is off, the power switch or fuse holder is faulty; open the device and check whether the power switch and fuse holder are melted.
2. Check whether the transmission structure between the belt and the shaft is loose, falling off or stuck;
3. If the above conditions are normal, check whether the motor has a working rotation sound. If not, the motor is faulty.
It is recommended that when cleaning an incompatible cup type, the middle short-bristled brush can be installed on the outer shaft for use.
1. Re-tighten the shaft;
2. Open the device, re-align the motor and tighten the screws.
The device needs to be opened to check whether water has entered the internal terminals, whether the connecting wires have fallen off, or whether the terminals have melted, causing the internal circuits to connect to the metal casing, causing a short circuit and tripping.